Power chain

From utility feed to rack, on one diagram

Model the whole power chain, see headroom at every step against de-rated capacity, and take a feed out on screen to find what would be overloaded.

Power chain · Hall 2UPS-A200 kWPDU-A1feed ARPP-A1-03feed AA1-03-0710 kW ratedRack A04PDU-AUtility and generator > UPS > floor PDU > RPP > circuit > rack PDU > rackFeed meters · Rack A04Feed A6.3 of 8 kWrated 10 kW · de-rated 8 kW · allocated 6.3 kWFeed B6.1 of 8 kWrated 10 kW · de-rated 8 kW · allocated 6.1 kWFail Feed A✕RPP-B1-03 at 104%✓0 devices unpoweredLoad moved to feed B suppliesSingle-feed devicesTwo or more power supplies,all on one feed, are listed.Draw 200 W · 150 W per outletBands: under 80 · 80 to 95 · over 95%
01

The full chain

Utility feed and generator, UPS, floor PDU, RPP, circuit, rack PDU and rack, each unit linked to the one above it.

02

Headroom with banding

Green under 80%, amber from 80 to 95% and red above 95%, against de-rated capacity where it is recorded.

03

Test a feed failure

Fail feed lists every unit pushed over 100% and every device left without power.

How it works

From setup to answer in four steps

  1. Build the chain

    Add units and circuits and put each on Feed A, B or C, STS, or not assigned.

  2. Cord the devices

    Cording a device to a PDU outlet stamps the outlet's circuit on its power port and recalculates allocated watts.

  3. Read the loads

    Load is the sum of watts allocated to outlets, rolled up to every unit above, with headroom at each step.

  4. Fail a feed

    Take out Feed A or B and see where the load moves and what goes over.

In the console

What you can do

Single-line diagram and tree

The Power panel shows a single-line diagram and a tree on site, room, rack, infrastructure unit and power circuit records. On a rack it shows only that rack's chain, with the rack highlighted.

Power panelChain for rack A04UPS-A200 kWPDU-A1feed ARPP-A1-03feed ACircuit A1-03-0710 kW rated, 8 kW de-ratedRack A04 PDU-A6.3 kW

Feed meters on every rack

Each rack shows a Feed A meter and a Feed B meter, captioned with rated, de-rated and allocated kW. A warning appears when every PDU in a rack is on one feed, and when placing a device would push a feed over its de-rating.

Feed metersRack A04Feed A6.3 of 8 kWFeed B6.1 of 8 kW

Single-corded kit, found

Single-feed devices lists any device with two or more power supplies all on one feed, so redundancy that exists on paper is the redundancy you have.

Fail feed resultFail Feed ARPP-B1-03104%Devices unpowered0Load moved tofeed B supplies
FAQ

Frequently asked questions

What does the power chain cover?

Utility feed and generator through UPS, floor PDU, RPP and circuit to the rack PDU and rack.

Is headroom based on nameplate?

It uses de-rated capacity where recorded, otherwise rated, against the watts allocated to each outlet.

Can we test losing a feed?

Yes. Fail feed moves load to the other supplies and lists every unit pushed over 100% and any device left without power.

Will it spot single-corded kit?

Yes. It lists devices whose power supplies all sit on one feed.

Can we see measured power?

The room power panel shows measured kW beside allocated kW per rack, with the reading's source and age.