Telemetry and environment

Measured, next to what you planned

Readings land beside the plan. See sensors on the floor, chart their history with limits drawn in, and compare measured kW with allocated kW rack by rack.

Telemetry · sensor historyTemperature & Humidity 1 · A04 front inlet18°22°26°30°34°warning 27 °Ccritical 32 °C-24 h-18 h-12 h-6 hnow24 hours7 days30 daysHumidity45 %RHLast reading 3 min agosource EkkoSense20.5 to 22.5 °C / 24 hRack A04 powermeasured 2.4 kWallocated 3.0 kW
01

Sensors on the plan

Drag a sensor onto the floor or a rack. It is drawn with an icon per sensor family and coloured by alarm state.

02

History against limits

Charts cover 24 hours, 7 days and 30 days, with warning and critical limits drawn as lines.

03

Measured against allocated

The room power panel puts measured kW beside allocated kW for each rack, with the reading's source and age.

How it works

From setup to answer in four steps

  1. Add a telemetry source

    Give it an endpoint, a saved credential and a poll interval of 15 minutes or less.

  2. Map the points

    Map each external point to a power meter, environmental sensor, power circuit or rack field, with its own unit and scale.

  3. Readings arrive

    A polling service reads sources every 5 minutes, keeps every reading as history and updates the mapped records hourly.

  4. Review

    Chart history, spot stale points and compare measured with allocated power.

In the console

What you can do

Fourteen sensor types, thirteen positions

Temperature, humidity, differential pressure, airflow, water leak, leak rope, smoke, door contact and more, mounted at the rack front inlet, rear exhaust, cold aisle, hot aisle, underfloor, CRAC or CRAH and elsewhere. Each holds warning and critical high and low limits, a dew point warning and calibration dates.

Sensor recordTemperature & Humidity 1PositionA04 front inletWarning high27 °CCritical high32 °CHumidity45 %RH

Stale points are flagged

Readings are converted to the field's unit, with W, kW and MW all shown as kW. A point silent for 30 minutes is flagged as stale, so a quiet feed never looks like a healthy one.

Telemetry pointsPoint statusRack A04 powerlast reading 3 min agoCold aisle sensorlast reading 6 min agoUnderfloor sensorstale, silent 30 min

Network device health too

Network devices are polled over SNMP every 5 minutes by the collector, with hourly CPU, memory, traffic and power draw history on each device and a fleet monitoring dashboard.

Device monitoringcore-rtr-01CPUhourly historyMemoryhourly historyTraffichourly historyPower drawhourly history
FAQ

Frequently asked questions

Which monitoring systems can feed it?

Telemetry sources connect through an endpoint, a saved credential and a poll interval. Ask us which of your systems are supported.

How often are readings collected?

Every 5 minutes. Mapped records update hourly and every reading is kept as history.

Can we see sensors on the floor plan?

Yes. Sensors are placed on the plan or a rack and coloured by alarm state.

How far back can we look?

Charts cover 24 hours raw, 7 days hourly and 30 days at 4-hourly, with limits drawn as lines.

Can we compare real power use with what we allocated?

Yes. Per rack, on the room power panel.