Room and floor planner

Plan the floor before you touch it

Open any room as a 2D floor plan or a 3D view, drop racks onto the tile grid and see at once whether they fit, clear the doors and face the right way.

Room planner · Hall 2Hall 2 Zone Acold aisleA01A02A03A04A05A06A07A08B01B02B03B04B05B06B07B08CRAC 1CRAC 2PDCcoldoor 900 mmHall 2 · 12.0 x 9.6 mColour by kWunder 80%80 to 95%over 95%A049.6 of 10 kW600 x 1000 mmrear clearance 600 mmFloor rated 1,200 kg/m²Aisles: 1 cold, 2 hot2D plan3D viewUndo · Redo · Save
01

Racks that cannot be misplaced

Every drop is checked against the room edge, other racks, door clearances and no-go zones before it is accepted.

02

Aisles worked out for you

Hot and cold aisles come from the way racks face, with warnings for racks facing the wrong way and containment set per aisle.

03

Try it without touching live

Save a layout to a plan scenario, or describe what you need and let Generate layout draw ranked options.

How it works

From setup to answer in four steps

  1. Set up the room

    Give a room its size and tile size and the raised floor tile grid is laid out for you.

  2. Draw what is already there

    Add doors with their swing, columns, cooling units, power cabinets, risers, no-go zones and cable entries, each with its own keep-clear distance.

  3. Place the racks

    Drag racks onto the floor. They snap square to whole tiles, or to a 100 mm grid when you hold Alt, and rotate in 90 degree steps.

  4. Review and save

    Colour racks by power, weight or cooling headroom, switch layers on and off, then save. Nothing is written until you do, and there is undo and redo.

In the console

What you can do

Start from the drawing you already have

Load an image, a PDF page or an ASCII DXF drawing as the background. Scale it by clicking two points a known distance apart, then set offset, rotation and opacity. The calibration is saved with the room.

Background drawingCalibrate drawingPoint A to point B12.0 mOffsetx 0.4 m, y 0.2 mRotation0 degreesOpacity60%

Placement that checks itself

A rack outside the room, overlapping another rack, blocking a door clearance or sitting in a no-go zone is refused. Front and rear service clearances come from the rack or its rack type.

Placement checkDrop rack B09Inside the roompassOverlaps another rackpassDoor clearance 900 mmblockedRear clearance 600 mmpass

Describe a layout and get options

Type a request such as six 8 kW racks, N+1 power, hot aisle containment. Generate layout draws up to three ranked layouts, each checked for placement, power and cooling. The one you accept is saved as a plan scenario, never straight onto live records.

Generate layoutSix 8 kW racks, N+1, hot aisle containmentLayout 1placement, power, cooling passLayout 2cooling needs reviewLayout 3placement pass
FAQ

Frequently asked questions

Can I start from our existing CAD drawing?

Yes. Load an image, a PDF page or an ASCII DXF, then calibrate it by clicking two points a known distance apart.

Is there a 3D view?

Yes. The planner switches between a 2D plan and a 3D view of the same room, and each room also has a read-only 3D view.

What stops people placing racks where they cannot go?

Every drop is checked against the room edge, other racks, door and service clearances, and no-go zones.

Does it understand hot and cold aisles?

It works out aisles from the way racks face, warns about racks facing the wrong way, and lets you set containment per aisle.

Can I try a layout without changing the live record?

Yes. Save to a plan scenario, or use Generate layout, whose accepted proposals become scenarios.

Can it suggest a layout?

Describe what you need, for example six 8 kW racks with N+1 power, and it draws up to three ranked layouts checked for power and cooling.